Building Filters
Type 70.1 Ti Fixed-Angle Titanium Rotor
Platform: Floor Prep | Rotor type: Fixed-Angle (Ultracentrifugation) | Angle: 24 | Maximum rpm: 70,000 rpm | Max g-force: 450,000 xg | K-factor: 36 | Adapters: 303313, 303376, 303401, 303402, 303448, 303624, 3050...
Krefeld, DeutschlandAQUIOS CL Flow Cytometer System with UPS, 100-120V
- Hersteller: Flow
Regulatory status: IVD | Resolution: 0.5 μm diameter particles. HPCV is <2% to <4% depending on the laser. | Performance: <600 MESF for APC|<600 MESF for FITC|<300 MESF for PE | Flow cell: BioSense 150 μm x 450 r...
Krefeld, Deutschland- Krefeld, Deutschland
CytoFLEX V0-B3-R3 Flow Cytometer (6 Detectors, 2 Lasers)
Regulatory status: RUO | Weight: | | Width: | | Depth: | | Height: |
Krefeld, DeutschlandCytoFLEX V3-B3-R3 Flow Cytometer (9 Detectors, 3 Lasers)
Regulatory status: RUO | Weight: | | Width: | | Depth: | | Height: |
Krefeld, DeutschlandCytoFLEX V2-B5-R3 Flow Cytometer (10 Detectors, 3 Lasers)
Regulatory status: RUO | Weight: | | Width: | | Depth: | | Height: |
Krefeld, DeutschlandCytoFLEX V2-B4-R3 Flow Cytometer (9 Detectors, 3 Lasers)
Regulatory status: RUO | Weight: | | Width: | | Depth: | | Height: |
Krefeld, DeutschlandCytoFLEX V0-B3-R2 Flow Cytometer (5 Detectors, 2 Lasers)
Regulatory status: RUO | Weight: | | Width: | | Depth: | | Height: |
Krefeld, DeutschlandTi-15 Zonal Rotor with B29 Core, Titanium
Platform: Floor Prep | Rotor type: Zonal (Ultracentrifugation) | Maximum rpm: 32,000 rpm | Max g-force: 102,000 xg | K-factor: 468 | Number of tubes: 8 x 13.5 mL
Krefeld, DeutschlandOptima™ Max-XP Tabletop Ultracentrifuge
Platform: Tabletop UCF | Maximum speed: 150,000 RPM | Maximum g-force: 1,019,000 xg | Biosafe: No | Acceleration: 10 acceleration profiles | Deceleration: 11 deceleration profiles | Max capacity volume range: 0 -...
Krefeld, Deutschland- Krefeld, Deutschland
- Krefeld, Deutschland
- Krefeld, Deutschland
Kaluza C Analysis Software 1 Year, 1-User (Single)
Compatibility: Kaluza C Analysis can load any listmode file that is compliant with the FCS standard up through version 3.1. | Plot types: Add All Plots, Cell Cycle Analysis Plots, Comparison Plots, Contour Plots,...
$1,493 USDKrefeld, DeutschlandCytoFLEX SRT V0-B2-Y5-R3 Cell Sorter (10 Colors, 3 Lasers)
Regulatory status: RUO | Signal processing: Digital system with 7-decade display | Detection: Photodiodes | Lasers: 488 nm, 561 nm, 638 nm | Optical filters: 450/45, 525/40 (2), 585/42, 610/20 (2), 660/10 (2), 67...
Krefeld, Deutschland